Eight Standard Points For LED Energy Saving Lamp Detection

Feb. 27, 2019

LED energy-saving lamps are a general term for the industry. There are many subdivided products, such as LED street lights, LED High Bay Light , LED tunnel lights, LED Flood Light and LED panel lights. At present, the specifications and standards for LED energy-saving lamps in China are becoming more and more strict, so certification testing has become the focus of work for LED lamp manufacturers. Below I will share with you 8 key points of LED energy-saving lamp testing standards:

1, material

According to the standard requirements, the energy-saving lamp housing material must be above the V-1 level, so the transparent polymer housing must be of V-1 or higher. The product casing must reach the V-1 rating and its thickness must be greater than or equal to the thickness required for the V-1 grade of the raw material.

2, drop test

According to the requirements of the product standard, the product should simulate the drop test that may occur during the actual use, and the product should fall from the height of 0.91 m to the hard board. The outer casing of the product should not be broken to expose the dangerous parts inside. When the manufacturer chooses the material to make the product casing, this test must be done in advance to avoid the loss caused by the mass production failure.

3, electric strength

The transparent housing encloses the power module inside, and the transparent housing material must meet the electrical strength requirements. According to the standard requirements, based on the condition of 120 volts in North America, the internal high-voltage live parts and the outer casing should be able to withstand the 1240 volt AC resistance test.

4, power module

The power module is an important part of the LED energy-saving lamp, and the power module mainly adopts the switching power supply technology. According to the type of power module, you can consider testing and certification with different standards.

5, insulation requirements

Due to the limited internal space of the LED energy-saving lamps, in the structural design, attention should be paid to the insulation requirements between the dangerous live parts and the accessible metal parts. The insulation can be a space distance and a creepage distance, or it can be an insulating sheet.